Home > Product Center > Products > Passive devices
Gas sensor | Gas sensors
TGS832

 tgs832.pdf

TGS832

Target gases:Halocarbon gas

Features:

  • High sensitivity to refrigerant gases

  • Quick response

  • Long term stability

  • Uses simple electrical circuit

Application

  • Portable and fixed installation refrigerant leak detectors


TGS2600

 tgs2600.pdf

TGS2600

Target gases: Air contaminants(hydrogen, ethanol, etc.)

Features:

  • Low power consumption

  • High sensitivity to gaseous air contaminants

  • Long life and low cost

  • Uses simple electrical circuit

  • Small size 

Application

  • Air cleaners

  • Ventilation control

  • Air quality monitors


TGS2602

 tgs2602.pdf

TGS2602

Target gases:Air contaminants(VOCs, ammonia, H2S, etc.)

Features:

  • High sensitivity to VOCs and odorous gases

  • Low power consumption

  • High sensitivity to gaseous air contaminants

  • Long life

  • Uses simple electrical circuit

  • Small size 

Application

  • Air cleaners

  • Ventilation control

  • Air quality monitors

  • VOC monitors

  • Odor monitors


TGS2603

 tgs2603.pdf

TGS2603

Target gases: Aircontaminants(Trimethylamine, methyl mercaptan, etc.)

Features:

  • Low power consumption

  • High sensitivity to amine-series and sulfurous odor gases

  • High sensitivity to food odors

  • Long life and low cost

  • Uses simple electrical circuit 

Application

  • Air cleaners

  • Ventilation control

  • Deodorizer control

  • Air quality monitors


TGS2610

 tgs2610(EN).pdf

TGS2610

Target gases: Butane, Propane

Features:

  • Low power consumption

  • High sensitivity to LP and its component gases (e.g. propane and butane)

  • Long life and low cost

  • Uses simple electrical circuit

Application

  • Residential LP leak detectors and alarms

  • Portable LP detectors

  • LP gas and vapor detection


TGS2610-D00

 tgs2610-02.pdf

TGS2610-D00

Target gases: Butane, Propane

Features:

  • Low power consumption

  • High sensitivity to LP and its component gases (e.g. propane and butane)

  • Long life and low cost

  • Uses simple electrical circuit

Application

  • Residential LP leak detectors and alarms

  • Portable LP detectors

  • LP gas and vapor detection


TGS2611-C00

 tgs2611-1(EN).pdf

TGS2611-C00

Target gases: Methane

Features:

  • Low power consumption

  • High sensitivity to methane

  • Long life and low cost

  • Uses simple electrical circuit

Application

  • Domestic gas alarms

  • Portable gas detectors

  • Gas leak detector for gas appliances


TGS2611-E00

 tgs2611_02(EN).pdf

TGS2611-E00

Target gases: Methane

Features:

  • Low power consumption

  • High sensitivity to methane

  • Long life and low cost

  • Uses simple electrical circuit

Application

  • Domestic gas alarms

  • Portable gas detectors

  • Gas leak detector for gas appliances


TGS2612

 TGS2612(EN).pdf

TGS2612

Target gases: Methane, Propane, Butane

Features:

  • Low power consumption

  • Similar sensitivity at same %LEL levels for both methane and LP gas

  • Long life and low cost

  • Uses simple electrical circuit

Application

  • Residential LNG and LPG alarms

  • Portable combustible gas leak detectors

  • Detectors for LNG and LPG


TGS2620

 tgs2620.pdf

TGS2620

Target gases: Alcohol, Solvent vapors

Features:

  • Low power consumption

  • High sensitivity to alcohol and organic solvent vapors

  • Long life and low cost

  • Uses simple electrical circuit

Application

  • Alcohol testers

  • Organic vapor detectors/alarms

  • Solvent detectors for factories, dry cleaners, and semiconductor industries


TGS3830

 tgs3830.pdf

TGS3830

Target gases: Halocarbon gas

Features:

  • Low power consumption

  • High sensitivity to R-134a

  • Quick response to R-134a

Application

  • Portable refrigerant leak detector


TGS387

 tgs3870-f00_rev03.pdf

TGS387

Target gases: Methane, Carbon Monoxide

Features:

  • Miniature size and low power consumption

  • High sensitivity and selectivity to both methane and carbon monoxide (CO)

  • Low sensitivity to alcohol vapor

  • Long life and low cost

Application

  • Combination methane and carbon monoxide detectors


TGS5042-A00

 tgs5042_01(EN).pdf

TGS5042-A00

Target gases: Carbon monoxide

Features:

  • Battery operable

  • High repeatability/selectivity to CO

  • Linear relationship between CO gas concentration and sensor output

  • Simple calibration

  • Long life

  • UL recognized component

  • Meets UL2034, EN50291, and RoHS requirements

Application

  • Residential and commercial CO detectors

  • CO monitors for industrial applications

  • Ventilation control for indoor parking garages

  • Fire detection


TGS5042-B00

 tgs5042_02(EN).pdf

TGS5042-B00

Target gases: Carbon monoxide

Features:

  • Battery operable

  • High repeatability/selectivity to CO

  • Linear relationship between CO gas concentration and sensor output

  • Simple calibration

  • Long life

  • UL recognized component

  • Meets UL2034, EN50291, and RoHS requirements

Application

  • Residential and commercial CO detectors

  • CO monitors for industrial applications

  • Ventilation control for indoor parking garages

  • Fire detection


TGS5141

 tgs5141(en).pdf

TGS5141

Target gases: Carbon monoxide

Features

  • Ultra compact

  • Battery operable

  • High repeatability/selectivity to CO

  • Linear relationship between CO gas concentration and sensor output

  • Simple calibration

  • Long life

  • UL recognized component

  • Meets UL2034, EN50291, and EN54-31 requirements

Application

  • Residential and commercial CO detectors

  • Fire detection


TGS6812-D00

 tgs6812(EN).pdf

TGS6812-D00

Target gases: Hydrogen, Methane, Butane, Propane

Features

  • Linear output

  • Long life

  • Small sensitivity to alcohol

  • Sensitive to hydrogen, methane, and LP gas

Application

  • Hydrogen and combustible gas leak detectors for fuel cells


KE-12

 tgs6810.pdf

KE-12

Target gases: Oxygen

Features

  • Long life

  • Virtually no influence from CO2, CO, H2S, NOx, H2

  • Low cost

  • Operates in normal ambient temperatures

  • Stable output signal

  • No external power supply required for sensor operation

  • No warmup time is required

Application

  • Medical - Anesthetic instruments, respirators, oxygen-enrichers

  • Biotechnology - Oxygen incubators

  • Food industry - Refrigeration, greenhouses

  • Safety - Air conditioners, oxygen detectors, fire detectors


KE-25

 ke_25.pdf

KE-25

Target gases: Oxygen

Features

  • Long life

  • Virtually no influence from CO2, CO, H2S, NOx, H2

  • Low cost

  • Operates in normal ambient temperatures

  • Stable output signal

  • No external power supply required for sensor operation

  • No warmup time is required

Application

  • Medical - Anesthetic instruments, respirators, oxygen-enrichers

  • Biotechnology - Oxygen incubators

  • Food industry - Refrigeration, greenhouses


TGS6810-D00

 tgs6810.pdf

TGS6810-D00

Target gases: Methane, Propane, Butane

Features

  • Linear output

  • Long life

  • Small sensitivity to alcohol

  • Sensitive to both methane and LP gas 

Application

  • Residential LNG and LPG alarms

  • Detectors for LNG and LPG


KE-50

 ke_50(EN).pdf

KE-50

Target gases: Oxygen

Features

  • Long life

  • Virtually no influence from CO2, CO, H2S, NOx, H2

  • Low cost

  • Operates in normal ambient temperatures

  • Stable output signal

  • No external power supply required for sensor operation

  • No warmup time is required 

Application

  • Medical - Anesthetic instruments, respirators, oxygen-enrichers

  • Biotechnology - Oxygen incubators

  • Food industry - Refrigeration, greenhouses

  • Safety - Air conditioners, oxygen detectors, fire detectors


SK-25

 sk-25f.pdf

SK-25

Target gases: Oxygen

Features

  • Virtually no influence from CO2, CO, H2S, NO, H2

  • Temperature compensation circuit included

  • Good linearity

  • No position dependency

  • Stable output signal

  • No external power supply required for sensor operation

  • No warmup time is required

Application

  • Safety - Air conditioners, oxygen detectors, fire detectors, fuel cell systems

  • Measurement - Oxygen monitors in flue gas

  • Biotechnology - Oxygen incubators, anaerobic cultivators

  • Food industry - Refrigeration, greenhouses


FECS40-1000

 fecs40-1000.pdf

FECS40-1000

Target gases: Carbon monoxide

Features

  • High selectivity to CO

  • Quick response to CO

  • Linear output

  • Stable baseline

  • Unique leak-proof structure

Application

  • Portable and fixed installation CO monitors

  • CO detectors

  • Ventilation control for indoor parking garages


FECS41-250

 fecs41-250(en).pdf

FECS41-250

Target gases: Nitric oxide

Features

  • High selectivity to NO

  • Quick response to NO

  • Linear output

  • Stable baseline

  • Unique leak-proof structure

 Application

  • Portable and fixed installation NO monitors

  • NO detectors

  • Ventilation control for indoor parking garages


FECS42-20

 fecs42-20.pdf

FECS42-20

Target gases: Nitrogen dioxide

Features

  • High selectivity to NO2

  • Quick response to NO2

  • Linear output

  • Stable baseline

  • Unique leak-proof structure

 Application

  • Portable and fixed installation NO2 monitors

  • NO2 detectors

  • Ventilation control for indoor parking garages


FECS43-20

 fecs43-20(EN).pdf

FECS43-20

Target gases: Nitrogen dioxide

Features

  • High selectivity to NO2

  • Quick response to NO2

  • Linear output

  • Stable baseline

  • Unique leak-proof structure

Application

  • Portable and fixed installation NO2 monitors

  • NO2 detectors

  • Ventilation control for indoor parking garages


FECS44-1000 / 5000

 fecs44h.pdf

FECS44-1000 / 5000

Target gases: Ammonia

Features

  • High selectivity to NH3

  • Small influence by H2S

  • Excellent durability to NH3 exposure

  • Linear output

  • Stable baseline

  • Unique leak-proof structure

Application

  • Portable and fixed installation NH3 monitors

  • NH3 detectors

  • Ammonia leak detection in refrigerators


FECS44-100/200

 fecs44-100-200(EN).pdf

FECS44-100/200

Target gases: Ammonia

Features

  • High selectivity to NH3

  • Small influence by H2S

  • Excellent durability to NH3 exposure

  • Linear output

  • Stable baseline

  • Unique leak-proof structure

Application

  • Portable and fixed installation NH3 monitors

  • NH3 detectors

  • Ammonia leak detection in refrigerators


FECS45-10

 fecs45-10.pdf

FECS45-10

Target gases: Chlorine

Features

  • High selectivity to Cl2

  • Linear output

  • Stable baseline

  • Unique leak-proof structure

Application

  • Portable and fixed installation Cl2 monitors

  • Cl2 detectors


FECS50-100

 fecs50-100(en).pdf

FECS50-100

Target gases: Hydrogen sulfide

Features

  • High selectivity to H2S

  • Quick response to H2S

  • Small influence by CO

  • Linear output

  • Stable baseline

  • Unique leak-proof structure

Application

  • Portable and fixed installation H2S monitors

  • H2S detectors