Mechanical and electrical products | Fan motors
AC fan motors

 06030PB.pdf

06030PB

Features:

  • Motor Structure:Shaded Pole Induction Motor

  • Motor Protection:Impedance Protection

  • Insulation Resistance:Min 100M ohm by DC 500V Megger

  • Dielectric Withstand Voltage:AC1800V 3s

  • Allowable Ambient Temperature Range:

  • -10deg.C - +70deg.C (Operating)

  • -40deg.C - +70deg.C (Storage)

  • non-condensing environmentOld model name:2412PS


 PT4720.pdf

PT4720

Features:

  • Motor Structure:3-phase 2pole

  • Motor Protection:Thermal Protect

  • Insulation Resistance:100MOhm or over with a DC500V Megger

  • Dielectric Withstand Voltage:AC1800V 1s

  • Allowable Ambient Temperature Range:

  • -20deg.C~+60deg.C(Operating)

  • -40deg.C~+70deg.C(Storage)

  • *no condensation permissible state plractice.


 02510SS.pdf

02510SS

Features:

  • Motor Protection:Auto Restart / Polarity Protection

  • Insulation Resistance:10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage:AC700V 1s

  • Allowable Ambient Temperature Range :-10deg.C - +70deg.C (Operating)

  • -40deg.C - +70deg.C (Storage)

  • non-condensing environment


 04020VA.pdf

04020VA

Features:

  • Motor Protection:Auto Restart / Polarity Protection

  • Insulation Resistance:10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage:AC700V 1s

  • Allowable Ambient Temperature Range :-10deg.C - +70deg.C (Operating)

    -40deg.C - +70deg.C (Storage)

  • non-condensing environment


 04520GA.pdf

04520GA

Features:

  • Motor Protection:Auto Restart / Polarity Protection

  • Insulation Resistance:10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage:AC700V 1s

  • Allowable Ambient Temperature Range :
    -10deg.C - +70deg.C (Operating)
    -40deg.C - +70deg.C (Storage)

  • non-condensing environment

 05020GA.pdf

05020GA

Features:

  • Motor Protection: Auto Restart / Polarity Protection

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range :

    K、L Class: -10deg.C - +70deg.C (Operating)

    M Class: -10deg.C - +60deg.C (Operating)

    -40deg.C - +70deg.C (Storage)

  • non-condensing environment

 R150H Series.pdf

R150H Series

Features:

  • Motor Protection: Locked rotor, Reverse polarity

  • Insulation Resistance: 10M Ohm min, measured with 500V DC between all leads shorted together and case

  • Dielectric Withstand Voltage: AC500V 1minuteAllowable Ambient Temperature Range:

    -30 deg.C - +70 deg.C (Operating)

    -40 deg.C - +80 deg.C (Storage)

  • non-condensing environment

 F175H系列.pdf

F175H Series

Features:

  • Motor Protection: Locked rotor, Reverse polarity

  • Insulation Resistance: 10M Ohm min, measured with 500V DC between all leads shorted together and case

  • Dielectric Withstand Voltage: AC500V 1minute

  • Allowable Ambient Temperature Range:
    -30 deg.C - +70 deg.C (Operating)
    -40 deg.C - +80 deg.C (Storage)

  • non-condensing environment

 60DCF-485.pdf

60DCF-485/60DCF-486/60DCF-487/70DCF-373/70DCF-374

Features:

  • Operating Temp. : 0deg.C - +50deg.C (no condensation)

  • Storage Temp.: -20deg.C - +65deg.C

  • Insulation Class : Class B

  • Insulation Resistance : 10 M Ohm min. at 500 VDC

  • Dielectric Strength
    Blower : 1500 VAC for 1 min.
    Driver : 1500 VAC for 1 min.

  • Operation Guarantee
    Overcurrent protection
    Locked rotor protection
    Abnormal temperature rise protection

  • Safety Standard:
    Blower : IEC/EN/UL62368-1, UL507, CSA-C22.2 No. 113-18
    Driver : IEC/EN/UL62368-1, UL61800-5-1, CSA-C22.2 No. 274-17

  • ※For TUV certification, please check the TüV Rheinland certificate database or contact us.

 08025MB.pdf

08025MB

Features:

  • Motor Structure: Shaded Pole Induction Motor

  • Motor Protection: Impedance Protection

  • Insulation Resistance: Min 100M ohm by DC 500V Megger

  • Dielectric Withstand Voltage: AC1800V 3s

  • Allowable Ambient Temperature Range:

    -10deg.C - +70deg.C (Operating)

    -40deg.C - +70deg.C (Storage)

  • non-condensing environmentOld model name:3110MS


 08038PB.pdf

08038PB

Features:

  • Motor Structure: Shaded Pole Induction Motor

  • Motor Protection: Impedance Protection

  • Insulation Resistance: Min 100M ohm by DC 500V Megger

  • Dielectric Withstand Voltage: AC1800V 3s

  • Allowable Ambient Temperature Range:

    -10deg.C - +70deg.C (Operating)

    -40deg.C - +70deg.C (Storage)

  • non-condensing environmentOld model name:3115PS


 09225PB.pdf

09225PB

Features:

  • Motor Structure:Shaded Pole Induction Motor

  • Motor Protection:Impedance Protection

  • Insulation Resistance:Min 100M ohm by DC 500V Megger

  • Dielectric Withstand Voltage:AC1800V 3s

  • Allowable Ambient Temperature Range:

    -10deg.C - +70deg.C (Operating)

    -40deg.C - +70deg.C (Storage)

  • non-condensing environmentOld model name:3610PS

 09238SB.pdf

09238SB

Features:

  • Motor Structure:Shaded Pole Induction Motor

  • Motor Protection:Impedance Protection

  • Insulation Resistance:Min 100M ohm by DC 500V Megger

  • Dielectric Withstand Voltage:AC1800V 3s

  • Allowable Ambient Temperature Range:

    -10deg.C - +70deg.C (Operating)

    -40deg.C - +70deg.C (Storage)

  • non-condensing environmentOld model name:3615HS


 11925PB.pdf

11925PB

Features:

  • Motor Structure: Shaded Pole Induction Motor

  • Motor Protection: Impedance Protection

  • Insulation Resistance: Min 100M ohm by DC 500V Megger

  • Dielectric Withstand Voltage: AC1800V 3s

  • Allowable Ambient Temperature Range:

    -10deg.C - +70deg.C (Operating)

    -40deg.C - +70deg.C (Storage)

  • non-condensing environmentOld model name: 4710PS


 11938MB.pdf

11938MB

Features:

  • Motor Structure:Shaded Pole Induction Motor

  • Motor Protection:Impedance Protection

  • Insulation Resistance:Min 100M ohm by DC 500V Megger

  • Dielectric Withstand Voltage:AC1800V 3s

  • Allowable Ambient Temperature Range:
    -10deg.C - +70deg.C (Operating)
    -40deg.C - +70deg.C (Storage)

  • non-condensing environmentOld model name:4715MS

 11938MB 特别版.pdf

11938MB Special Edition

Features:

  • Motor Structure: Shaded Pole Induction Motor

  • Motor Protection: Impedance Protection

  • Insulation Resistance: Min 100M ohm by DC 500V Megger

  • Dielectric Withstand Voltage: AC1800V 3s

  • Allowable Ambient Temperature Range:
    -10deg.C - +70deg.C (Operating)
    -40deg.C - +70deg.C (Storage)

  • non-condensing environment

 11938TB 金属刀片.pdf

11938TB Metal Blades

Features:

  • Motor Structure:Shaded Pole Induction Motor

  • Motor Protection:Thermal Protection

  • Insulation Resistance:Min 100M ohm by DC 500V Megger

  • Dielectric Withstand Voltage:AC1800V 3s

  • Allowable Ambient Temperature Range:
    -10deg.C - +60deg.C (Operating)
    -40deg.C - +70deg.C (Storage)

  • non-condensing environmentOld model name:4715TS Metal Blades

 11938SB.pdf

11938SB

Features:

  • Motor Structure: Shaded Pole Induction Motor

  • Motor Protection: Thermal Protection

  • Insulation Resistance: Min 100M ohm by DC 500V Megger

  • Dielectric Withstand Voltage: AC1800V 3s

  • Allowable Ambient Temperature Range:

    -10deg.C - +65deg.C (Operating)

    -40deg.C - +70deg.C (Storage)

    non-condensing environmentOld model name: 4715HS

 15038PB 金属刀片.pdf

15038PB Metal Blades

Features:

  • Motor Structure: Capacitor-Run Induction Motor

  • Motor Protection: Thermal Protection

  • Insulation Resistance: Min 100M ohm by DC 500V Megger

  • Dielectric Withstand Voltage: AC1800V 3s

  • Allowable Ambient Temperature Range:

    -10deg.C - 60deg.C (Operating)

    -40deg.C - +70deg.C (Storage)

    non-condensing environmentOld model name:5915PC Metal Blades

 15038PB塑料刀片.pdf

15038PB Plastic Blades

Features:

  • Motor Structure:Capacitor-Run Induction Motor

  • Motor Protection:Thermal Protection

  • Insulation Resistance:Min 100M ohm by DC 500V Megger

  • Dielectric Withstand Voltage:AC1800V 3s

  • Allowable Ambient Temperature Range:

    -10deg.C - +70deg.C (Operating)

    -40deg.C - +70deg.C (Storage)

    non-condensing environmentOld model name:5915PC Plastic Blades


 RT5318.pdf

RT5318

Features:

  • Motor Structure:3-phase 2pole

  • Motor Protection:Thermal Protect

  • Insulation Resistance:100MOhm or over with a DC500V Megger

  • Dielectric Withstand Voltage:AC1800V 1s

  • Allowable Ambient Temperature Range:

    -20deg.C~+60deg.C(Operating)

    -40deg.C~+70deg.C(Storage)

    *no condensation permissible state plractice.

 PT5921.pdf

PT5921

Features:

  • Motor Structure:3-phase 2pole

  • Motor Protection:Thermal Protect

  • Insulation Resistance:100MOhm or over with a DC500V Megger

  • Dielectric Withstand Voltage:AC1800V 1s

  • Allowable Ambient Temperature Range:

    -20deg.C〜+60deg.C (Operating)

    -40deg.C〜+70deg.C (Storage)

    *no condensation permissible state plractice.

 RT6323.pdf

RT6323

Features:

  • Motor Structure: 3-phase 2pole

  • Motor Protection: Thermal Protect

  • Insulation Resistance: 100MOhm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC1800V 1s

  • Allowable Ambient Temperature Range:

    -20deg.C〜+60deg.C (Operating)

    -40deg.C〜+70deg.C (Storage)

    *no condensation permissible state plractice.

 RT6925.pdf

RT6925

Features:

  • Motor Structure:3-phase 2pole

  • Motor Protection:Thermal Protect

  • Insulation Resistance:100MOhm or over with a DC500V Megger

  • Dielectric Withstand Voltage:AC1800V 1s

  • Allowable Ambient Temperature Range:

    -20deg.C〜+60deg.C (Operating)

    -40deg.C〜+70deg.C (Storage)

    *no condensation permissible state plractice.

 PT7126.pdf

PT7126

Features:

  • Motor Structure: 3-phase 2pole

  • Motor Protection: Thermal Protect

  • Insulation Resistance: 100MOhm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC1800V 1s

  • Allowable Ambient Temperature Range:

    -20deg.C〜+60deg.C (Operating)

    -40deg.C〜+70deg.C (Storage)

    *no condensation permissible state plractice.

 PT8330.pdf

PT8330

Features:

  • Motor Structure: 3-phase 2pole

  • Motor Protection: Thermal Protect

  • Insulation Resistance: 100MOhm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC1800V 1s

  • Allowable Ambient Temperature Range:

    -20deg.C〜+60deg.C (Operating)

    -40deg.C〜+70deg.C (Storage)

    *no condensation permissible state plractice.

 PT9833.pdf

PT9833

Features:

  • Motor Structure:3-phase 2pole

  • Motor Protection:Thermal Protect

  • Insulation Resistance:100MOhm or over with a DC500V Megger

  • Dielectric Withstand Voltage:AC1800V 1s

  • Allowable Ambient Temperature Range:

    -20deg.C〜+60deg.C (Operating)

    -40deg.C〜+70deg.C (Storage)

    *no condensation permissible state plractice.

 PT13839.pdf

PT13839

Features:

  • Motor Structure: 3-phase 4pole

  • Motor Protection: Thermal Protect

  • Insulation Resistance: 100MOhm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC1800V 1s

  • Allowable Ambient Temperature Range:

    -20deg.C〜+60deg.C (Operating)

    -40deg.C〜+70deg.C (Storage)

    *no condensation permissible state plractice.

 03010SS.pdf

03010SS

Features:

  • Motor Protection: Auto Restart / Polarity Protection

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range :

    -10deg.C - +70deg.C (Operating)

    -40deg.C - +70deg.C (Storage)

    non-condensing environment


 03510SS.pdf

03510SS

Features:

  • Motor Protection: Auto Restart / Polarity Protection

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range :

    -10deg.C - +70deg.C (Operating)

    -40deg.C - +70deg.C (Storage)

    non-condensing environment


 03515SS.pdf

03515SS

Features:

  • Motor Protection: Auto Restart / Polarity Protection

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range :

    -10deg.C - +70deg.C (Operating)

    -40deg.C - +70deg.C (Storage)

    non-condensing environment

 04010SS.pdf

04010SS

Features:

  • Motor Protection: Auto Restart / Polarity Protection

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range:

    -10deg.C - +70deg.C (Operating)

    -40deg.C - +70deg.C (Storage)

    non-condensing environment


 04015SS.pdf

04015SS

Features:

  • Motor Protection: Auto Restart / Polarity Protection

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range : 12L, 12M, 12N, 24L, 24M

  • Class: -10deg.C - +70deg.C (Operating)

  • 24N Class:

    -10deg.C - +60deg.C (Operating)

    -40deg.C - +70deg.C (Storage)non-condensing environment

 2004KL.pdf

2004KL

Features:

  • Motor Protection: Auto Restart / Polarity Protection

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range :

    -10deg.C - +70deg.C (Operating)

    -40deg.C - +70deg.C (Storage)

    non-condensing environment


 06015KA.pdf

06015KA

Features:

  • Motor Protection: Auto Restart / Polarity Protection

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range :

    -10deg.C - +60deg.C (Operating)

    -40deg.C - +60deg.C (Storage)

    non-condensing environment


 06015SS.pdf

06015SS

Features:

  • Motor Protection: Auto Restart / Polarity Protection

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range :

    -10deg.C - +70deg.C (Operating)

    -40deg.C - +70deg.C (Storage)

    non-condensing environment


 06020SA.pdf

06020SA

Features:

  • Motor Protection: Auto Restart / Polarity Protection

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range :

    -10deg.C - +70deg.C (Operating)

    -40deg.C - +70deg.C (Storage)

    non-condensing environment


 06020SS.pdf

06020SS

Features:

  • Motor Protection: Auto Restart / Polarity Protection

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range :

    -10deg.C - +70deg.C (Operating)

    -40deg.C - +70deg.C (Storage)

    non-condensing environment


 06025SA.pdf

06025SA

Features:

  • Motor Protection: Auto Restart / Polarity Protection

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range : 

    -10deg.C - +70deg.C (Operating)

    -40deg.C - +70deg.C (Storage)

    non-condensing environment


 06025SS.pdf

06025SS

Features:

  • Motor Protection: Auto Restart / Polarity Protection

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range :L, M

  • Class: -10deg.C - +70deg.C (Operating)

  • N, R Class:

    -10deg.C - +60deg.C (Operating)

    -40deg.C - +70deg.C (Storage) non-condensing environment


 2806KL.pdf

2806KL

Features:

  • Motor Protection: Auto Restart / Polarity Protection

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range :

    -10deg.C - +70deg.C (Operating)

    -40deg.C - +70deg.C (Storage)

    non-condensing environment


 2810KL.pdf

2810KL

Features:

  • Motor Protection: Auto Restart / Polarity Protection

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range :

  • -10deg.C - +70deg.C (Operating)

  • -40deg.C - +70deg.C (Storage)

  • non-condensing environment


 08015SS.pdf

08015SS

Features:

  • Motor Protection: Auto Restart / Polarity Protection

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range : L、M

  • Class: -10℃ ~ +70℃ (Operating)

  • N Class:

    -10℃ ~ +60℃ (Operating)

    -40℃ ~ +70℃ (Storage)non-condensing environment


 08020SA.pdf

08020SA

Features:

  • Motor Protection: Auto Restart / Polarity Protection

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range :

    -10deg.C - +70deg.C (Operating)

    -40deg.C - +70deg.C (Storage)

    non-condensing environment


 08020SS.pdf

08020SS

Features:

  • Motor Protection: Auto Restart / Polarity Protection

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range :

    -10deg.C - +70deg.C (Operating)

    -40deg.C - +70deg.C (Storage)

    non-condensing environment

 08025SA.pdf

08025SA

Features:

  • Motor Protection: Auto Restart / Polarity Protection

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range : L, M,

  • N Class:

    -10deg.C - +70deg.C (Operating)R Class:

    -10deg.C - +60deg.C (Operating)

    -40deg.C - +70deg.C (Storage)non-condensing environment


 08025SS.pdf

08025SS
Features:
  • Motor Protection: Auto Restart / Polarity Protection

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range : L、M

  • Class:

    -10deg.C - +70deg.C (Operating)

  • N、Q Class:

    -10deg.C - +60deg.C (Operating)

    -40deg.C - +70deg.C (Storage)non-condensing environment

 09225SA.pdf

09225SA

Features:

  • Motor Protection: Auto Restart / Polarity Protection

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range :

    -10deg.C - +70deg.C (Operating)

    -40deg.C - +70deg.C (Storage)

    non-condensing environment

 11925SA.pdf

11925SA

Features:

  • Motor Protection: Auto Restart / Polarity Protection

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range : L, M,

  • N Class:

    -10deg.C - +70deg.C (Operating)

  • R Class: 

    -10deg.C - +60deg.C (Operating)

    -40deg.C - +70deg.C (Storage)non-condensing environment


 4712KL.pdf

4712KL

Features:

  • Motor Protection: Auto Restart / Polarity Protection

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range : B20, B30, B40 Class:

    -10deg.C - +70deg.C (Operating)B50 Class: 

    -10deg.C - +50deg.C (Operating)

    -40deg.C - +70deg.C (Storage)non-condensing environment


 11938KA.pdf

11938KA

Features:

  • Motor Protection: Auto Restart / Polarity Protection

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range : L、M

  • Class:

    -10deg.C - +70deg.C (Operating)

  • N Class:

    -10deg.C - +40deg.C (Operating)

    -40deg.C - +70deg.C (Storage)non-condensing environment


 5015KL.pdf

5015KL

Features:

  • Motor Protection: Auto Restart / Polarity Protection

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range : 04W-B30,04W-B40,

  • 05W-B30,07W-B30 Class

    :-10deg.C - +60deg.C (Operating)04W-B50, 05W-B40,05W-B50,07W-B40,07W-B50 Class

    :-10deg.C - +50deg.C (Operating)

    :-40deg.C - +70deg.C (Storage)non-condensing environment

 04028VA.pdf

04028VA

Features:

  • Motor Protection: Auto Restart / Polarity Protection

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range :

    -10deg.C - +70deg.C (Operating)

    -40deg.C - +70deg.C (Storage)

    non-condensing environment


 06015VA.pdf

06015VA

Features:

  • Motor Protection: Auto Restart / Polarity Protection

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range :

    -10deg.C - +70deg.C (Operating)

    -40deg.C - +70deg.C (Storage)

    non-condensing environment


 06020VA.pdf

06020VA

Features:

  • Motor Protection: Auto Restart / Polarity Protection

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range :

    -10deg.C - +70deg.C (Operating)

    -40deg.C - +70deg.C (Storage)

    non-condensing environment

 06025VA.pdf

06025VA

Features:

  • Motor Protection: Auto Restart / Polarity Protection

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range :

    -10deg.C - +70deg.C (Operating)

    -40deg.C - +70deg.C (Storage)

    non-condensing environment


 06025VE Potting II.pdf

06025VE Potting II

Features:

  • Motor Protection: Auto Restart / Polarity Protection

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range :

    -10deg.C - +70deg.C (Operating)

    -40deg.C - +70deg.C (Storage)

    non-condensing environmentIP Code: IP68

 06025VC Aluminum.pdf

06025VC Aluminum

Features:

  • Motor Protection: Auto Restart / Polarity Protection

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range :

    -10deg.C - +85deg.C (Operating)

    -40deg.C - +85deg.C (Storage)

    non-condensing environment


 08025DC.pdf

08025DC

Features:

  • Motor Protection: Auto Restart / Polarity Protection

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range :

    -10deg.C - +85deg.C (Operating)

    -40deg.C - +85deg.C (Storage)

    non-condensing environment

 08025VE Potting II.pdf

08025VE Potting II

Features:

  • Motor Protection: Auto Restart / Polarity Protection

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range :

    -10deg.C - +60deg.C (Operating)

    -40deg.C - +70deg.C (Storage)

    non-condensing environmentIP Code:IP68

 09225VA.pdf

09225VA

Features:

  • Motor Protection: Auto Restart / Polarity Protection

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range :

    -10deg.C - +70deg.C (Operating)

    -40deg.C - +70deg.C (Storage)

    non-condensing environment


 09232VA.pdf

09232VA

Features:

  • Motor Protection: Auto Restart / Polarity Protection

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range :

    -10deg.C - +70deg.C (Operating)

    -40deg.C - +70deg.C (Storage)

    non-condensing environment


 12038VA(E-Type).pdf

12038VA(E-Type)

Features:

  • Motor Protection: Auto Restart / Polarity Protection

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range : M, N, P, Q

  • Class:

    -10deg.C - +70deg.C (Operating)

  • R Class:

    -10deg.C - +60deg.C (Operating)

    -40deg.C - +70deg.C (Storage)

    non-condensing environment

 15025PA.pdf

15025PA

Features:

  • Motor Protection: Auto Restart / Polarity Protection

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range :

    -10deg.C - +70deg.C (Operating)

    -40deg.C - +70deg.C (Storage)

    non-condensing environment

 15050VA.pdf

15050VA

Features:

  • Motor Protection: Auto Restart / Polarity Protection

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range :

    -10deg.C - +70deg.C (Operating)

    -40deg.C - +70deg.C (Storage)

    non-condensing environment


 17250VA.pdf

17250VA

Features:

  • Motor Protection: Auto Restart / Polarity Protection

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range :

    -10deg.C - +70deg.C (Operating)

    -40deg.C - +70deg.C (Storage)

    non-condensing environment


 06038RA.pdf

06038RA

Features:

  • Motor Protection: Auto Restart / Polarity Protection

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range : Q, R Class:

    -10deg.C - +70deg.C (Operating)S Class:

    -10deg.C - +70deg.C (Operating: 12V)S Class:

    -10deg.C - +60deg.C (Operating: 24V)

    -40deg.C - +70deg.C (Storage)non-condensing environment


 08038RA.pdf

08038RA

Features:

  • Motor Protection: Auto Restart / Polarity Protection

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range :

    -10deg.C - +70deg.C (Operating)

    -40deg.C - +70deg.C (Storage)

    non-condensing environment

 09238RA(D-type).pdf

09238RA(D-type)

Features:

  • Motor Protection: Auto Restart / Polarity Protection

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range :

    -10deg.C - +70deg.C (Operating)

    -40deg.C - +70deg.C (Storage)

    non-condensing environment


 06025MA.pdf

06025MA

Features:

  • Motor Protection: Auto Restart / Polarity Protection

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range : L, M, N Class:

    -10deg.C - +70deg.C (Operating)R Class:

    -10deg.C - +60deg.C (Operating)

    -40deg.C - +70deg.C (Storage)non-condensing environment


 11938MA.pdf

11938MA

Features:

  • Motor Protection: Auto Restart / Polarity Protection

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range :

    -10deg.C - +70deg.C (Operating)

    -40deg.C - +70deg.C (Storage)

    non-condensing environment


 03828DA.pdf

03828DA

Features:

  • Motor Protection: Auto Restart / Polarity Protection

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range : 

    -10deg.C - +70deg.C (Operating)

    -40deg.C - +70deg.C (Storage)

    non-condensing environment


 04028DA.pdf

04028DA

Features:

  • Motor Protection: Auto Restart / Polarity Protection

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range : 

    -10deg.C - +70deg.C (Operating)

    -30deg.C - +70deg.C (Storage)

    non-condensing environment


 04028DA(H-Type Single Phase).pdf

04028DA(H-Type Single Phase)

Features:

  • Motor Protection: Auto Restart / Polarity Protection

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range P, Q, R, S Class :

    -10deg.C - +70deg.C (Operating)

    -40deg.C - +70deg.C (Storage)

    non-condensing environment


 04028DA(H-Type Three Phase).pdf

04028DA(H-Type Three Phase)

Features:

  • Motor Protection: Auto Restart / Polarity Protection

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range :

    -10deg.C - +60deg.C (Operating)

    -40deg.C - +70deg.C (Storage)

    non-condensing environment

 04056DA.pdf

04056DA

Features:

  • Motor Protection: Auto Restart / Polarity Protection

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range :

    -10deg.C - +70deg.C (Operating)

    -40deg.C - +70deg.C (Storage)

    non-condensing environment


 04056EA (Counter Rotating Fan).pdf

04056EA (Counter Rotating Fan)

Features:

  • Motor Protection: Auto Restart / Polarity Protection

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range :

    -10deg.C - +60deg.C (Operating)

    -30deg.C - +70deg.C (Storage)

    non-condensing environment


 06025DA.pdf

06025DA

Features:

  • Motor Protection: Auto Restart / Polarity Protection

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range :

    -10deg.C - +70deg.C (Operating)

    -40deg.C - +70deg.C (Storage)

    non-condensing environment


 06038DA(Single Phase).pdf

06038DA(Single Phase)

Features:

  • Motor Protection: Auto Restart / Polarity Protection

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range :

    -10deg.C - +60deg.C (Operating)

    -30deg.C - +70deg.C (Storage)

    non-condensing environment


 06056EA.pdf

06056EA

Features:

  • Motor Protection: Auto Restart / Polarity Protection

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range :

    -10deg.C - +70deg.C (Operating)

    -30deg.C - +70deg.C (Storage)

    non-condensing environment


 08025DA.pdf

08025DA

Features:

  • Motor Protection: Auto Restart / Polarity Protection

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range :

    -10deg.C - +60deg.C (Operating)※P Class

    -10deg.C - +70deg.C (Operating)※N Class

    -40deg.C - +70deg.C (Storage)

    non-condensing environment

 08025DA(D-Type).pdf

08025DA(D-Type)

Features:

  • Motor Protection: Auto Restart / Polarity Protection

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range :

    -10deg.C - +70deg.C (Operating)

    -40deg.C - +70deg.C (Storage)

    non-condensing environment

 08038DA(E-Type Single Phase).pdf

08038DA(E-Type Single Phase)

Features:

  • Motor Protection: Auto Restart / Polarity Protection

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range :

    -10deg.C - +70deg.C (Operating)

    -40deg.C - +70deg.C (Storage)

    non-condensing environment

 08038DA(E-Type Three Phase).pdf

08038DA(E-Type Three Phase)

Features:

  • Motor Protection: Auto Restart / Polarity Protection

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range :

    -10deg.C - +70deg.C (Operating)

    -40deg.C - +70deg.C (Storage)

    non-condensing environment

 09238DA.pdf

09238DA

Features:

  • Motor Protection: Auto Restart / Polarity Protection

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range :

    -10deg.C - +60deg.C (Operating)

    -40deg.C - +70deg.C (Storage)

    non-condensing environment


 080A0EA.pdf

080A0EA

Features:

  • Motor Protection: Auto Restart / Polarity Protection

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range :

    -10deg.C - +60deg.C (Operating)

    -30deg.C - +60deg.C (Storage)

    non-condensing environment

 12038MA.pdf

12038MA

Features:

  • Motor Protection: Auto Restart / Polarity Protection

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range :

    -10deg.C - +70deg.C (Operating)

    -30deg.C - +70deg.C (Storage)

    non-condensing environment


 06615JS for Evaporator.pdf

06615JS for Evaporator

Features:

  • Motor Protection: Auto Restart

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range :

    -40deg.C - +40deg.C (Operating)

    -40deg.C - +60deg.C (Storage)

    non-condensing environment


 08015JE for Evaporator.pdf

08015JE for Evaporator

Features:

  • Motor Protection: Auto Restart

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range :

    -40deg.C - +40deg.C (Operating)

    -40deg.C - +60deg.C (Storage)

    non-condensing environment


 09225JS for Condenser.pdf

09225JS for Condenser

Features:

  • Motor Protection: Auto Restart

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range :

    -10deg.C - +70deg.C (Operating)

    -40deg.C - +70deg.C (Storage)

    non-condensing environment


 09232JE for Evaporator.pdf

09232JE for Evaporator

Features:

  • Motor Protection: Auto Restart

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range :

    -40deg.C - +40deg.C (Operating)

    -40deg.C - +70deg.C (Storage)

    non-condensing environment

 11338JE for Evaporator.pdf

11338JE for Evaporator

Features:

  • Motor Protection: Auto Restart

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range :

    -40deg.C - +40deg.C (Operating)

    -40deg.C - +70deg.C (Storage)

    non-condensing environment


 12537JE for Evaporator.pdf

12537JE for Evaporator

Features:

  • Motor Protection: Auto Restart

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range :

    -40deg.C - +40deg.C (Operating)

    -40deg.C - +70deg.C (Storage)

    non-condensing environment


 12539JA for Condenser.pdf

12539JA for Condenser

Features:

  • Motor Protection: Auto Restart

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range :

    -10deg.C - +70deg.C (Operating)

    -40deg.C - +70deg.C (Storage)

    non-condensing environment


 12539JE for Evaporator.pdf

12539JE for Evaporator

Features:

  • Motor Protection: Auto Restart

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range :

    -40deg.C - +40deg.C (Operating)

    -40deg.C - +70deg.C (Storage)

    non-condensing environment


 15047JA for Condenser.pdf

15047JA for Condenser

Features:

  • Motor Protection: Auto Restart

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range : J CLASS:

    -10deg.C - +70deg.C (Operating)K CLASS:

    -10deg.C - +60deg.C (Operating)

    -40deg.C - +70deg.C (Storage)non-condensing environment


 17240JA for Condenser.pdf

17240JA for Condenser

Features:

  • Motor Protection: Auto Restart

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range :

    -10deg.C - +70deg.C (Operating)

    -40deg.C - +70deg.C (Storage)

    non-condensing environment


 10030GE for Evaporator.pdf

10030GE for Evaporator

Features:

  • Motor Protection: Auto Restart

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range :

    -40deg.C - +40deg.C (Operating)

    -40deg.C - +70deg.C (Storage)

    non-condensing environment


 12038GE for Evaporator.pdf

12038GE for Evaporator

Features:

  • Motor Protection: Auto Restart

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range :

    -40deg.C - +40deg.C (Operating)

    -40deg.C - +60deg.C (Storage)

    non-condensing environment


 05125GS.pdf

05125GS

Features:

  • Motor Protection: Auto Restart / Polarity Protection

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range :

    -10deg.C - +70deg.C (Operating)

    -40deg.C - +70deg.C (Storage)

    non-condensing environment

 06023GA.pdf

06023GA

Features:

  • Motor Protection: Auto Restart / Polarity Protection (except N Class)

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range :

    L、M Class:-10deg.C - +70deg.C (Operating)

    N Class: -10deg.C - +60deg.C (Operating)

    -40deg.C - +70deg.C (Storage)

    non-condensing environment


 06023GS(Single Phase).pdf

06023GS(Single Phase)

Features:

  • Motor Protection: Auto Restart

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range :

    L、M Class: -10℃ ~ +70℃ (Operating)

    N Class:

    -10℃ ~ +60℃ (Operating)

    -40℃ ~ +70℃ (Storage)

    non-condensing environment


 06023GS(Three Phase).pdf

06023GS(Three Phase)

Features:

  • Motor Protection: Auto Restart / Polarity Protection

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range :

    -10deg.C - +60deg.C (Operating)

    -40deg.C - +70deg.C (Storage)

    non-condensing environment


 06920GA.pdf

06920GA

Features:

  • Motor Protection: Auto Restart / Polarity Protection

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range :

    -10deg.C - +70deg.C (Operating)

    -40deg.C - +70deg.C (Storage)

    non-condensing environment

 07525GA.pdf

07525GA

Features:

  • Motor Protection: Auto Restart / Polarity Protection

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range :

    -10deg.C - +70deg.C (Operating)

    -40deg.C - +70deg.C (Storage)

    non-condensing environment


 07530GA.pdf

07530GA

Features:

  • Motor Protection: Auto Restart / Polarity Protection

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range :

    07530GA-24M-AA:

    -10deg.C - +60deg.C (Operating)

  • K · L · 12M Class:

    -10deg.C - +70deg.C (Operating)

    -40deg.C - +70deg.C (Storage)

    non-condensing environment

 07530GS.pdf

07530GS

Features:

  • Motor Protection: Auto Restart / Polarity Protection

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range :

    -10deg.C - +70deg.C (Operating)

    -40deg.C - +70deg.C (Storage)

    non-condensing environment


 file_01_20.pdf

08028GS

Features:

  • Motor Protection: Auto Restart

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range :

    -10deg.C - +60deg.C (Operating)

    -40deg.C - +70deg.C (Storage)

    non-condensing environment


 09533GA.pdf

09533GA

Features:

  • Motor Protection: Auto Restart / Polarity Protection

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range :

    -10deg.C - +60deg.C (Operating)

    -40deg.C - +70deg.C (Storage)

    non-condensing environment

 09533GS.pdf

09533GS

Features:

  • Motor Protection: Auto Restart / Polarity Protection

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range :

    -10deg.C - +60deg.C (Operating)

    -40deg.C - +70deg.C (Storage)

    non-condensing environment


 12032GA.pdf

12032GA

Features:

  • Motor Protection: Auto Restart / Polarity Protection

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range :

    -10deg.C - +60deg.C (Operating)

    -40deg.C - +70deg.C (Storage)

    non-condensing environment

 14539GA.pdf

14539GA

Features:

  • Motor Protection: Auto Restart / Polarity Protection

  • Insulation Resistance: 10M ohm or over with a DC500V Megger

  • Dielectric Withstand Voltage: AC700V 1s

  • Allowable Ambient Temperature Range :

    -10deg.C - +60deg.C (Operating)

    -40deg.C - +70deg.C (Storage)

    non-condensing environment

 R172A系列.pdf

R172A Series

Features:

  • Motor Protection: Locked rotor, Reverse polarity

  • Insulation Resistance: 10M Ohm min, measured with 500V DC between all leads shorted together and case

  • Dielectric Withstand Voltage: AC500V 1minuteAllowable Ambient Temperature Range: 

    -30 deg.C - +70 deg.C (Operating)

    -40 deg.C - +80 deg.C (Storage)

    non-condensing environment

 R172H系列.pdf

R172H Series

Features:

  • Motor Protection: Locked rotor, Reverse polarity

  • Insulation Resistance: 10M Ohm min, measured with 500V DC between all leads shorted together and case

  • Dielectric Withstand Voltage: AC500V 1minuteAllowable Ambient Temperature Range:

    -30 deg.C - +70 deg.C (Operating)

    -40 deg.C - +80 deg.C (Storage)

    non-condensing environment

 R200A系列.pdf

R200A Series

Features:

  • Motor Protection: Locked rotor, Reverse polarity

  • Insulation Resistance: 10M Ohm min, measured with 500V DC between all leads shorted together and case

  • Dielectric Withstand Voltage: AC500V 1minuteAllowable Ambient Temperature Range:

    -30 deg.C - +70 deg.C (Operating)

    -40 deg.C - +80 deg.C (Storage)

    non-condensing environment


 F175G系列.pdf

F175G Series

Features:

  • Motor Protection: Locked rotor, Reverse polarity

  • Insulation Resistance: 10M Ohm min, measured with 500V DC between all leads shorted together and case

  • Dielectric Withstand Voltage: AC500V  1minute

  • Allowable Ambient Temperature Range:

    -30 deg.C - +60 deg.C (F175G1-Operating),

    -30 deg.C - +55 deg.C (F175G3-Operating)

    -40 deg.C - +70 deg.C (Storage)

    non-condensing environment

  • IP Code: IP68


 F220C系列.pdf

F220C Series

Features:

  • Motor Protection: Locked rotor, Reverse polarity

  • Insulation Resistance: 10M Ohm min, measured with 500V DC between all leads shorted together and case

  • Dielectric Withstand Voltage: AC500V 1minute

  • Allowable Ambient Temperature Range:

    -30 deg.C - +70 deg.C (Operating)

    -40 deg.C - +80 deg.C (Storage)

    non-condensing environment

 F225A系列.pdf

F225A 系列

Features:

  • Motor Protection: Locked rotor, Reverse polarity

  • Insulation Resistance: 10M Ohm min, measured with 500V DC between all leads shorted together and case

  • Dielectric Withstand Voltage: AC500V 1minute

  • Allowable Ambient Temperature Range:

    -30 deg.C - +70 deg.C (Operating)

    -40 deg.C - +80 deg.C (Storage)

    non-condensing environment

 F225C 系列.pdf

F225C Series

Features:

  • Motor Protection: Locked rotor, Reverse polarity

  • Insulation Resistance: 10M Ohm min, measured with 500V DC between all leads shorted together and case

  • Dielectric Withstand Voltage: AC500V 1minute

  • Allowable Ambient Temperature Range:

    -30 deg.C - +70 deg.C (Operating)

    -40 deg.C - +80 deg.C (Storage)

    non-condensing environment

 F225T系列.pdf

F225T Series

Features:

  • Motor Protection: Locked rotor, Reverse polarity

  • Insulation Resistance: 10M Ohm min, measured with 500V DC between all leads shorted together and case

  • Dielectric Withstand Voltage: AC500V 1minute

  • Allowable Ambient Temperature Range:

    -30 deg.C - +70 deg.C (Operating)

    -40 deg.C - +80 deg.C (Storage)

    non-condensing environment

 F250A系列.pdf

F250A Series

Features:

  • Motor Protection: Locked rotor, Reverse polarity

  • Insulation Resistance: 10M Ohm min, measured with 500V DC between all leads shorted together and case

  • Dielectric Withstand Voltage: AC500V 1minute

  • Allowable Ambient Temperature Range:

    -30 deg.C - +70 deg.C (Operating)

    -40 deg.C - +80 deg.C (Storage)

    non-condensing environment

 F280A系列.pdf

F280A Series

Features:

  • Motor Protection: Locked rotor, Reverse polarity

  • Insulation Resistance: 10M Ohm min, measured with 500V DC between all leads shorted together and case

  • Dielectric Withstand Voltage: AC500V 1minute

  • Allowable Ambient Temperature Range:

    -30 deg.C - +70 deg.C (Operating)

    -40 deg.C - +80 deg.C (Storage)

    non-condensing environment

 04010UA.pdf

04010UA

Features:

  • Available operation temperature -40℃ ~ +105℃

  • Available 125℃ High temperature model

  • Available AEC-Q100 compliant electronics

DC fan motors
DC blower fan motors
High Power DC Fan motor
Fan units
High-pressure blowers
Automotive Fan motors

 04020UA.pdf

04020UA

Features:

  • Available operation temperature -40℃ ~ +105℃

  • Available 125℃ High temperature model

  • Available AEC-Q100 compliant electronics


 BLOM2515D.pdf

BLOM2515D

Features:

  • Available operation temperature -40℃ 〜 +105℃

  • Available 125℃ High temperature model

  • Available AEC-Q100 compliant electronics


 05015UA.pdf

05015UA

Features:

  • Available operation temperature -40℃ 〜 +105℃

  • Available 125℃ High temperature model

  • Available AEC-Q100 compliant electronics

 06025UA.pdf

06025UA

Features:

  • Available operation temperature -40℃ 〜 +105℃

  • Available 125℃ High temperature model

  • Available AEC-Q100 compliant electronics

  • Available IP68 compliant model (Potting Method *)


*The potting method overmold motor coil area by epoxy resin under special process of vacuum state.

The potting series take advantage of superior dust & oil proof.

 08038UA.pdf

08038UA

Features:

  • Available operation temperature -40℃ 〜 +105℃

  • Available 125℃ High temperature model

  • Available AEC-Q100 compliant electronics

  • Available IP68 compliant model (Potting Method *)


*The potting method overmold motor coil area by epoxy resin under special process of vacuum state.

The potting series take advantage of superior dust & oil proof.


 09225UA.pdf

09225UA

Features:

  • Available operation temperature -40℃ 〜 +105℃

  • Available 125℃ High temperature model

  • Available AEC-Q100 compliant electronics

  • Available IP68 compliant model (Potting Method *)


*The potting method overmold motor coil area by epoxy resin under special process of vacuum state.

The potting series take advantage of superior dust & oil proof.


 BLOM2325D.pdf

BLOM2325D

Features:

  • Available operation temperature -40℃ 〜 +105℃

  • Available 125℃ High temperature model

  • Available AEC-Q100 compliant electronics